Bulkhead Gates and Stop Logs
are normally used to isolate
equipments such as pumps, screens
and service gates for maintenance.
Where Bulkhead Gates are supplied
in one piece panels, Stop Logs
are furnished in multiple sections
for ease of handling and installation.
hese can be used in multiple
locations (slots) and can be
removed completely for storage.
|
|
 |
|
Balancing
valves are provided to facilitate
head balancing and gate removal.
Stop Logs can be supplied with
a automatic engaging disengaging
follower lifting beam to simplify
underwater installation and
removal. |
|
They are designed to be placed in slots or grooved channel
walls and are lifted and lowered with overhead or mobile
cranes. The gate has lifting lugs for handling. The slots or
grooves are lined or fabricated from steel or stainless steel for
ease of insertion and good fit with rubber seals on the
bulkhead gate. |
|
When equipped with a lintel seal, the gate can seal off heads
greater than the gate height.Rubber seals around the perimeter of the gate control leakage
effectively and are hydrostatically energized. |
|
|
Bulk head gates can be used in multiple locations (slots) and
can be removed completely for storage. They cannot be
inserted when significant flows or heads are present since the
only closing force is gravity. Removal against high differential
heads is not practical or possible. A small fill or balancing gate
or valve can be installed on the bulk head gate to facilitate
head balancing and gate removal. |